HOME » PRODUCTS » Standard Drive »A150 Series Standard Drive
A150 series drive is a new generation of standard vector inverter developed by Holip, using future-oriented modular design concept. The whole machine is divided into control unit(CU),power unit(PU),optional card,LCP and covers.Modules can be configured in the best way according to the application requirements, providing high flexibility for the applications.
plastics, textiles, machine tools, food packaging, chemicals, printing, building materials, stone, wire drawing, glass, ball mills, environmental, overloading fan machinery, etc.
Flexible | Reliable | ||
|
| ||
Easy to Use | |||
| |||
Communicative | |||
|
Item | Specification | |
Power supply | Supply voltage | Single/three phase 200~240V -20%~+10%; Three phase 380~480V -20%~+10%; |
Frequency | 48-62Hz; | |
Max. imbalance | 3% ; | |
Motor output | Output voltage | Three phase 0-100% of supply voltage |
Output frequency | 0-400Hz | |
IO board control terminals
| Input | 5 digital inputs (1 supports pulse input, pulse range: 1Hz~100kHz); 2 analog input, both can receive voltage or current signals. |
Output | 1 digital output (supports pulse output, pulse range: 1Hz~100kHz); 1 relay output; 1 analog input (supports current output or voltage output via parameter). | |
Power supply | 1 +10V, max current output 10mA; | |
Communication | RS+, RS-, max baud rate 115200bit/s; | |
Display | 8 segments, 5 numeric displays | Display frequency, warnings, status and so on; |
Indicator | Light FWD, REV, HZ, A, RPM display various status of the drive; | |
Data read-outs | Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state, analogue input , analogue output, 1-10 fault records and accumulated working time etc.; | |
Environment | Enclosure | IP20; |
Ambient temperature | -10℃~60℃, derating use when over 50℃; | |
Humidity | 5%-85% (95% without condensation); | |
Vibration test | ≤75kW: 1.14g; ≥90kW: 0.7g; | |
Max. altitude above sea level | 1000m, derating use when more than 1000 meters; | |
Motor cable length | Shield cable: 50 meters; Unshield cable: 100 meters; | |
Others | DC choke | none |
Braking unit | Built-in |
Main control functions | Control mode | V/F, VVC+; |
Start torque | 0.5Hz 150%; | |
Overload capacity | 150% 60s, 200% 1s; | |
PWM switch frequency | 2~16kHz ; | |
Speed setting resolution | Digital: 0.001Hz; Analogy: 0.5‰ of the max. operating frequency ; | |
Speed open-loop control accuracy | 30~4000 rpm: tolerance±8 rpm; | |
Control command source | LCP, digital terminal, local bus; | |
Frequency setting source | LCP, analog, pulse, local bus; | |
Ramp control | Selectable 4-speed steps ramp up and down times 0.05-3600.00s; | |
Basic Functions | Speed Open-loop Control; Process Closed-loop Control; Torque Open-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation; V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function; Counter; Timer;Jogging; Multi-speed Control via Digital input; Mechanical Braking; UP/DOWN; | |
Protection Functions | Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc. |
Model | Input voltage | Input current (A) | Output current (A) | Rated power (kW) | Power Dissipation (W) | Air flow rate (m3/h) | Net weight (kg) |
---|---|---|---|---|---|---|---|
A150-0D3723 | 1×200-240V | 6.3 | 2.5 | 0.37 | 18.2 | 0 | 0.8 |
3×200-240V | 3.6 | 2.5 | 17.3 | ||||
A150-0D7523 | 1×200-240V | 11.3 | 4.5 | 0.75 | 28.3 | 17.2 | 0.9 |
3×200-240V | 6.5 | 4.5 | 26.8 | ||||
A150-01D523 | 1×200-240V | 18.5 | 7.5 | 1.5 | 55.1 | 17.2 | 0.9 |
3×200-240V | 10.9 | 6.8 | 44.4 | ||||
A150-02D223 | 1×200-240V | 23.9 | 9.6 | 2.2 | 59.9 | 45.5 | 1.5 |
3×200-240V | 13.9 | 9.6 | |||||
A150-0D7543 | 3×380-440V | 3.1 | 2.1 | 0.75 | 35.6 | 0 | 0.8 |
3×440-480V | 2.8 | 1.9 | |||||
A150-01D543 | 3×380-440V | 5.5 | 3.8 | 1.5 | 43.3 | 17.2 | 0.9 |
3×440-480V | 5.0 | 3.4 | |||||
A150-02D243 | 3×380-440V | 7.3 | 5.1 | 2.2 | 59.6 | 17.2 | 0.9 |
3×440-480V | 6.6 | 4.6 | |||||
A150-04D043 | 3×380-440V | 12.9 | 9.0 | 4.0 | 101.6 | 45.5 | 1.5 |
3×440-480V | 11.6 | 8.1 | |||||
A150-05D543 | 3×380-440V | 18.9 | 13.0 | 5.5 | 128.5 | 90.0 | 2.0 |
3×440-480V | 17.1 | 11.7 | |||||
A150-07D543 | 3×380-440V | 24.5 | 17.0 | 7.5 | 188.7 | 90.0 | 2.0 |
3×440-480V | 22.1 | 15.3 |
Frame | Voltage & Power | Dimensions(mm) | ||||||
---|---|---|---|---|---|---|---|---|
3x200-240V | 3x380-480V | W | H | D | W1 | H1 | d | |
NA0-A | 0.37 kW | 0.75 kW | 72 | 170 | 150 | 60 | 150 | 4.5 |
NA-B | 0.75-1.5 kW | 1.5-2.2 kW | 72 | 185 | 150 | 55 | 175 | 4.5 |
NA1 | 2.2 kW | 4.0 kW | 88 | 215 | 155 | 70 | 205 | 4.5 |
NA2 | - | 5.5-7.5 kW | 100 | 250 | 160 | 80 | 240 | 4.5 |