Item | Specification | |
Power supply | Supply voltage | Three phase 380~480V -20%~+10%; DC voltage |
Frequency | 48-62Hz; | |
Max. imbalance | 3% ; | |
Main Motor output | Output voltage | Three phase 0-100% of supply voltage |
Output frequency | V/F : 0-400Hz , VVC+: 0-200Hz; | |
Fan Motor output | Output voltage | three phase 0-100% of supply voltage; |
Output frequency | V/F : 0-400Hz , VVC+: 0-200Hz; | |
220V Power | Output voltage | 220 ~250V(isolation power) |
Rated power | 50VA | |
IO board control terminals
| Input | 6 digital inputs ; 5 analogue input, one can receive voltage or current signal; one only can receive current signal; other can receive PT100 signals, RI1 can receive PT1000 signal; |
Output | 2 relay output; | |
Power supply | 1 24V, max current output 500mA(>=22kW); max current output 300mA(<=15kW) | |
Communication | 2 communication, max baud rate 115200bit/s; | |
Display | 8 segments, 5 numeric displays | Display frequency, warnings, status and so on; |
Indicator | Light FWD, REV, HZ, A, RPM display various status of the drive; | |
Data read-outs | Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state, analogue input , analogue output, 1-10 fault records and accumulated working time etc.; | |
Environment | Enclosure | IP20; |
Ambient temperature | -10℃~50℃, derating use when over 40℃; | |
Humidity | 5%-85% (95% without condensation); | |
Vibration test | 1.14g; | |
Max. altitude above sea level | 1000m, derating use when more than 1000 meters; | |
Motor cable length | Shield cable: 50 meters; Unshield cable: 100 meters; | |
Others | DC choke | ≥22kW Built-in |
Main frequency control functions | Control mode | V/F, Vector control; |
Start torque | 0.5Hz 150%; | |
Overload capacity | 150% 60s, 200% 1s; | |
PWM switch frequency | 2k~16kHz ; | |
Speed setting resolution | Digital: 0.001Hz; Analogy: 0.5‰ of the max. operating frequency ; | |
Speed open-loop control accuracy | 30~4000 rpm: tolerance±8 rpm; | |
Control command source | LCP, digital terminal, local bus; | |
Fan frequency control function | Control mode | V/F, Vector control |
Start torque | 0.5Hz 150% | |
Overload capacity | 150% 60s, 200% 1s; | |
PWM switch frequency | 2~16kHz; | |
Basic Functions | Speed Open-loop Control; Process Closed-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Automatic Voltage Regulation; V/F Control, Speed Limit; Current Limit; Flying Start; Reset Function; Counter; | |
Application Functions | Air Pressure control; Temperature control; Oil filter control; Many protection function; Air filter control; Oil separator control; Grease separator control; Lube control; Loading/unloading control; fan control; PID control; synchronous motor/ synchronous motor control | |
Protection Functions | Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc. |
Model | Input voltage | Input current (A) | load | Output current (A) | Rate power (kw) | Motor (kw) | Net weight (kg) |
---|---|---|---|---|---|---|---|
HLP-SK20007D543 | 3×380-440V50/60Hz | 26 | Fan | Contactor control | 0.22 | 4.8 | |
Main | 17.7 | 7.5 | 7.5 | ||||
HLP-SK200001143 | 37 | Fan | Contactor control | 0.37 | 7 | ||
Main | 25 | 11 | 11 | ||||
HLP-SK200001543 | 45 | Fan | Contactor control | 7 | |||
Main | 32 | 15 | 15 | ||||
HLP-SK200002243 | 48 | Fan | 4 | 1.5 | <=1.5 | 17.5 | |
Main | 45 | 22 | 22 | ||||
HLP-SK200003743 | 75 | Fan | 4 | 1.5 | <=1.5 | 23.5 | |
Main | 75 | 37 | 37 | ||||
HLP-SK200004543 | 90 | Fan | 5.3 | 2.2 | <=2.2 | 29 | |
Main | 91 | 45 | 45 | ||||
HLP-SK200005543 | 115 | Fan | 53 | 2.2 | <=2.2 | 29 | |
Main | 112 | 55 | 55 | ||||
HLP-SK200007543 | 158 | Fan | 12 | 5.5 | <=5.5 | 41 | |
Main | 150 | 75 | 75 | ||||
HLP-SK200009043 | 185 | Fan | 12 | 5.5 | <=5.5 | 41 | |
Main | 180 | 90 | 90 |
Model | W (mm) | H (mm) | D (mm) | W1 (mm) | H1 (mm) | d (mm) |
---|---|---|---|---|---|---|
HLP-SK20007D543 | 158 | 340 | 178 | 133 | 330 | 4.5 |
HLP-SK200001143 | 194 | 440 | 190 | 150 | 426 | 6.5 |
HLP-SK200001543 | 194 | 440 | 190 | 150 | 426 | 6.5 |
HLP-SK200002243 | 234 | 509 | 210 | 150 | 491 | 7 |
HLP-SK200003743 | 292 | 599 | 230 | 240 | 574 | 9 |
HLP-SK200004543 | 292 | 650 | 249 | 240 | 625 | 9 |
HLP-SK200005543 | 292 | 650 | 249 | 240 | 625 | 9 |
HLP-SK200007543 | 292 | 742 | 278 | 240 | 717 | 9 |
HLP-SK200009043 | 292 | 742 | 278 | 240 | 717 | 9 |
Model | W | H | D | W1 | H1 | d |
---|---|---|---|---|---|---|
HLP-SK200002243 | 234 | 635 | 210 | 150 | 491 | 7 |
HLP-SK200003743 | 292 | 727 | 230 | 240 | 574 | 9 |
HLP-SK200004543 | 292 | 773 | 249 | 240 | 625 | 9 |
HLP-SK200005543 | ||||||
HLP-SK200007543 | 292 | 872 | 278 | 240 | 717 | 9 |
HLP-SK200009043 |
Model | A | B | C | D | E | F | G | H | J | K | L | X | Y |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HLP-SK200002243 | 150 | 305 | 233 | 283 | 160 | 160 | 200 | 216 | 22 | 17 | 35 | 10 | 7 |
HLP-SK200003743 | 152 | 363 | 253 | 341 | 218 | 181 | 220 | 274 | 22 | 17 | 35 | 10 | 7 |
HLP-SK200004543 | 150 | 363 | 273 | 341 | 220 | 200 | 240 | 274 | 22 | 17 | 35 | 10 | 7 |
HLP-SK200005543 | |||||||||||||
HLP-SK200007543 | 152 | 363 | 303 | 341 | 218 | 181 | 269 | 274 | 22 | 17 | 35 | 10 | 7 |
HLP-SK200009043 |