HOME » PRODUCTS » Standard Drive »HLP-SH110 High Frequency Drive
HLP-SH110 series is Holip new generation high frequency drive. It has wide output frequency range from 0.0 to 3000.0Hz, good control performance and high precision steady speed.
Plastic, textile, machine tools, food packaging, chemical, printing and dyeing, building materials, stone, wire drawing machine, ceramics, glass, environmental protection and other industries
High Reliability | High Environmental Adaptability | ||
|
| ||
Excellent User Friendliness | |||
| |||
Excellent Control Performance | |||
|
Item | Specification | |
Power supply | Supply voltage | Single/three phase 200~240V -20%~+10%; Three phase 380~480V -20%~+10%; |
Frequency | 48-62Hz; | |
Max. imbalance | 3% ; | |
Motor output | Output voltage | Three phase 0-100% of supply voltage |
Output frequency | V/F : 0-400Hz , VVC+: 0-200Hz; | |
IO board control terminals
| Input | 6 digital inputs (1 supports pulse input, pulse range: 1Hz~100kHz); 2 analog input, both can receive voltage or current signals. |
Output | 2 digital output (1 supports pulse output, pulse range: 1Hz~100kHz); 2 relay output; 2 analog input (1 can be selected as current output or voltage output via jumper switch). | |
Power supply | 1 +10V, max current output 10mA; 1 24V, max current output 200mA; | |
Communication | RS+, RS-, max baud rate 115200bit/s; | |
Display | 8 segments, 5 numeric displays | Display frequency, warnings, status and so on; |
Indicator | Light FWD, REV, HZ, A, RPM display various status of the drive; | |
Data read-outs | Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state, analogue input , analogue output, 1-10 fault records and accumulated working time etc.; | |
Environment | Enclosure | IP20; |
Ambient temperature | -10℃~50℃, derating use when over 40℃; | |
Humidity | 5%-85% (95% without condensation); | |
Vibration test | ≤75kW: 1.14g; ≥90kW: 0.7g; | |
Max. altitude above sea level | 1000m, derating use when more than 1000 meters; | |
Motor cable length | Shield cable: 50 meters; Unshield cable: 100 meters; | |
Others | DC choke | ≥37kW Built-in |
Braking unit | ≤22kW Built-in |
Main control functions | Control mode | V/F, VVC+; |
Start torque | 0.5Hz 150%; | |
Overload capacity | 150% 60s, 200% 1s; | |
PWM switch frequency | 2k~16kHz ; | |
Speed setting resolution | Digital: 0.001Hz; Analogy: 0.5‰ of the max. operating frequency ; | |
Speed open-loop control accuracy | 30~4000 rpm: tolerance±8 rpm; | |
Control command source | LCP, digital terminal, local bus; | |
Frequency setting source | LCP, analog, pulse, local bus; | |
Ramp control | Selectable 4-speed steps ramp up and down times 0.05-3600.00s; | |
Basic Functions | Speed Open-loop Control; Process Closed-loop Control; Torque Open-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation; V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function; Counter; Timer; | |
Application Functions | Wobble Function; Jogging; Multi-speed Control via Digital input; SLC(including Order Control and Parallel Control); Mechanical Braking; UP/DOWN ; Catch up /Slow down; Relative Scaling Reference etc. | |
Protection Functions | Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc. |
Model | Input voltage | Input current (A) | Output current (A) | Rated power (kW) | Power Dissipation (W) | Air flow rate (m3/h) | Net weight (kg) |
---|---|---|---|---|---|---|---|
HLP-SH1100D3721 | 1x200-240V | 7.0 | 2.5 | 0.37 | 17.7 | 51 | 1.3 |
HLP-SH1100D7521 | 1x200-240V | 13.9 | 5.0 | 0.75 | 33.3 | 51 | 1.3 |
HLP-SH11001D521 | 1x200-240V | 20.6 | 7.5 | 1.5 | 53.8 | 51 | 1.3 |
HLP-SH11002D221 | 1x200-240V | 30.4 | 11 | 2.2 | 75.0 | 51 | 1.3 |
HLP-SH11003D721 | 1x200-240V | 49.7 | 17 | 3.7 | 115.7 | 51 | 2.0 |
HLP-SH1100D3723 | 3×200-240V | 4.0 | 2.5 | 0.37 | 16.8 | 51 | 1.3 |
HLP-SH1100D7523 | 3×200-240V | 8.0 | 5 | 0.75 | 31.5 | 51 | 1.3 |
HLP-SH11001D523 | 3×200-240V | 12.0 | 7.5 | 1.5 | 51.0 | 51 | 1.3 |
HLP-SH11002D223 | 3×200-240V | 17.7 | 11 | 2.2 | 73.7 | 51 | 1.3 |
HLP-SH11003D723 | 3×200-240V | 27.2 | 17 | 3.7 | 110.9 | 51 | 2.0 |
HLP-SH1100D7543 | 3×380-440V | 3.7 | 2.3 | 0.75 | 38.5 | 51 | 1.3 |
3×440-480V | 3.2 | 2.1 | |||||
HLP-SH11001D543 | 3×380-440V | 6.4 | 4 | 1.5 | 49.0 | 51 | 1.3 |
3×440-480V | 5.5 | 3.6 | |||||
HLP-SH11002D243 | 3×380-440V | 8.9 | 5.6 | 2.2 | 65.2 | 51 | 1.3 |
3×440-480V | 7.7 | 5.1 | |||||
HLP-SH11004D043 | 3×380-440V | 15.8 | 9.9 | 4.0 | 122.9 | 51 | 2.0 |
3×440-480V | 13.6 | 9 | |||||
HLP-SH11005D543 | 3×380-440V | 21.3 | 13.3 | 5.5 | 139.4 | 51 | 2.0 |
3×440-480V | 18.4 | 12.1 | |||||
HLP-SH11007D543 | 3×380-440V | 28.3 | 17.7 | 7.5 | 211.6 | 68 | 2.5 |
3×440-480V | 24.4 | 16.1 | |||||
HLP-SH110001143 | 3×380-440V | 35.9 | 25 | 11 | 262.4 | 124 | 5.8 |
3×440-480V | 31.4 | 22.7 | |||||
HLP-SH110001543 | 3×380-440V | 43.4 | 32 | 15 | 339.3 | 170 | 5.8 |
3×440-480V | 38.8 | 29.1 |
Voltage & Power | Dimensions(mm) | ||||||
---|---|---|---|---|---|---|---|
3x380-480V | A | B | C | D | E | F | G |
0.75-2.2kW | 104 | 125 | 194 | 210 | 152 | 4.5 | - |
4.0-5.5kW | 124 | 145 | 230 | 250 | 167 | 4.5 | - |
7.5kW | 133 | 155 | 243 | 263 | 177 | 4.5 | - |
11-15kW | 150 | 192 | 340 | 365 | 189 | 6.5 | - |
18.5-22kW | 150 | 216 | 395 | 420 | 194 | 6.5 | - |
30-45kW | 240 | 292 | 492 | 517 | 229 | 9 | - |
55-75kW | 240 | 292 | 537 | 562 | 249 | 9 | - |
90kW | 240 | 292 | 640 | 665 | 277 | 9 | - |
110-160kW | 220 | 350 | 765 | 799 | 375 | 10.5 | 280 |