HOME » PRODUCTS » Standard Drive »HLP-NV Multifunction Drive

HLP-NV Multifunction Drive

HLP-NV series drive is for the light industrial machinery market. Although its volume is small, but it has good performance and high reliability, coupled with a good user interface and sophisticated shape. It will bring you unexpected results.

Applications:

light industrial machinery market

Characteristic
High ReliabilityHigh Environmental Adaptability 
 

 

 
  • Book-type design, side by side mounting saves the user installation space 

Excellent User Friendliness 
 
  • Compact, beautiful appearance

  • ≥1.5kW models built-in breaking unit

 
Excellent Control Performance  
 
  • Use vector control algorithms, has high torque at low speed

  • Built-in electronic terminal relay (ETR)

  • Built-in simple PLC controller can achieve a variety of logic control

      
    Tech. Specifications
    Item  Specification
    Power supply Supply voltage

    Single/three phase 200~240V  -10%~+10%;

      Three phase 380~480V -10%~+10%;

    Frequency  48-62Hz;
    Max. imbalance   3% ;
    Motor output Output voltage   Three phase  0-100% of supply voltage
    Output frequency   V/F : 0-400Hz , VVC+: 0-200Hz;

    IO

    board

    control

    terminals

     

       
     Input

      5 digital inputs (1 supports pulse input, pulse range: 20Hz~5kHz);

      1 analog input, both can receive voltage or current signals.
     Output

      1 relay output;

      1 analog input (only supports current output).
     Power supply

      1 +10V, max current output 10mA;

      1 +24V, max current output 200mA;
     Communication  RS+, RS-, max baud rate 38400bit/s;
     Display   8 segments, 5 numeric displays   Display frequency, warnings, status and so on;
     Indicator Light FWD, REV, HZ, A, RPM display various status of the drive;
     Data read-outs   Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state,  analogue input , analogue output, 1-10 fault records and accumulated working time etc.;
     Environment     Enclosure  IP20;
     Ambient temperature  -10℃~50℃, derating use when over 40℃;
     Humidity  5%-85% (95% without condensation);
     Vibration test  1.14g;
     Max. altitude above sea level  1000m, derating use when more than 1000 meters;
     Motor cable length  Shield cable: 5 meters; Unshield cable: 50 meters;
    Others  DC choke  ≥18.5kW Built-in
     Braking unit

     ≥1.5kW Built-in

    Product Functions
    Main control functions Control mode V/F, VVC+;
    Start torque 0.5Hz 150%;
    Overload capacity 150% 60s;
    PWM switch frequency 2k~16kHz ;
    Speed setting resolution

    Digital: 0.01Hz;

    Analogy: 0.1% of the max. operating frequency;

    Speed open-loop control accuracy

    30~4000 rpm: tolerance±8 rpm;
    Control command source LCP, digital terminal, local bus;
    Frequency setting source LCP, analog, pulse, local bus;
    Ramp control Selectable 4-speed steps ramp up and down times 0.05-3600.00s;
    Basic Functions Speed Open-loop Control; Process Closed-loop Control;  AMT Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation;  V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function;   
    Application Functions Jogging;  Multi-speed  Control via Digital input; SLC(including Order Control and Parallel Control); Mechanical Braking; UP/DOWN ; Catch up /Slow down; Relative Scaling Reference etc.,

    Protection

    Functions
    Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMT Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc.
    Particular Specifications
    Model   Input voltage

     Rated power

    (kW) 

     Output current

    (A)

    Suitable motor

    (kW)
    HLPNV0D1821A 1x200-240V 50/60Hz 1.2  0.18  0.18 
    HLPNV0D1821B
    HLPNV0D3721A  1x200-240V 50/60Hz  2.2   0.37  0.37 
    HLPNV0D3721B
    HLPNV0D7521A   1x200-240V 50/60Hz
    4.2   0.75  0.75  
    HLPNV0D7521B 
    HLPNV01D521A  1x200-240V 50/60Hz   6.8   1.5   1.5  
    HLPNV01D521B 
    HLPNV02D221A 
    1x200-240V 50/60Hz   9.6   2.2   2.2  
    HLPNV02D221B 
    HLPNV0D2523A   3x200-240V 50/60Hz 
    1.5   0.25    0.25 
    HLPNV0D2523B  
    HLPNV0D3723A  
    3x200-240V 50/60Hz 
    2.2   0.37   0.37  
    HLPNV0D3723B  
    HLPNV0D7523A
    3x200-240V 50/60Hz 
    4.2   0.75   0.75  
    HLPNV0D7523B
    HLPNV01D523A
    3x200-240V 50/60Hz 
    6.8  1.5    1.5 

    HLPNV01D523B

    HLPNV02D223A
    3x200-240V 50/60Hz    9.6   2.2   2.2  
    HLPNV02D223B
    HLPNV03D723A  3x200-240V 50/60Hz 
    15.2   3.7   3.7  
    HLPNV03D723B 
    HLPNV0D3743A 
    3x200-240V 50/60Hz 
    1.2   0.37   0.37  
    HLPNV0D3743B 
    HLPNV0D7543A   3x200-240V 50/60Hz    2.2   0.75   0.75  
    HLPNV0D7543B 
    HLPNV01D543A   3x200-240V 50/60Hz    3.7   1.5   1.5  
    HLPNV01D543B 
    HLPNV02D243A  
    3x200-240V 50/60Hz    5.3   2.2   2.2  
    HLPNV02D243B  
    HLPNV03D043A    3x200-240V 50/60Hz   7.2   3.0   3.0  
    HLPNV03D043B
    HLPNV04D043A     3x200-240V 50/60Hz 
    9.0   4.0   4.0  
    HLPNV04D043B
    HLPNV05D543A   
    3x200-240V 50/60Hz    12.0   5.5   5.5  
    HLPNV05D543B 
    HLPNV07D543A
    3x200-240V 50/60Hz    15.5   7.5   7.5  
    HLPNV07D543B
    HLPNV001143A
    3x200-240V 50/60Hz    23.0   11.0    11.0 
    HLPNV001143B
    HLPNV001543A
    3x200-240V 50/60Hz    31.0   15.0   15.0  
    HLPNV001543B
    HLPNV18D543A
    3x200-240V 50/60Hz    37.0   18.5   18.5  
    HLPNV18D543B
    HLPNV002243A
    3x200-240V 50/60Hz    43.0   22.0    22.0 
    HLPNV002243B
    Installation Dimensions

    Voltage & Power 

     Dimensions

    (mm)

    1×200-240V 3x200-240V 3x380-480V
    A B C D E F G
    0.18-0.75kW 0.25-0.75kW 0.37-0.75kW 58 70 151 160 150 4.5 4.5
    1.5kW 1.5kW
    1.5-2.2kW   61 75 178 186 170 4.5 4.5
    2.2kW 2.2-3.7kW 3.0-7.5kW 76 90 230 239 196 4.5 4.5
    - - 11-15kW 97 125 273 292 243 7 7
    - - 18.5-22kW 137 165 316 335 252 7 7
    Welcome to Holip website
    If you need any help, please fill in the blanks below,
    we will contact you as soon as we receive your requirements.
    在线表单
    Your name :
    Your E-mail :
    The product model :
    Problem Description :