HOME » PRODUCTS » Standard Drive »HLP-A100 General Drive

HLP-A100 General Drive

HLP-A100 series is Holip new generation of general vector drive, with high reliability, high environmental adaptability, excellent user friendliness and excellent control performance features. It can be widely applied to many industries such as plastics, textiles, machine tools, food packaging, chemicals, printing, building materials, stone, wire drawing, glass, ball mills, environmental, overloading fan machinery, etc.

Applications:

plastics, textiles, machine tools, food packaging, chemicals, printing, building materials, stone, wire drawing, glass, ball mills, environmental, overloading fan machinery, etc.

Characteristic

High Reliability

High Environmental Adaptability


 
  • Long life design

  • Fan speed controllable

  • Strict design and test production system

 
  • Independent wind way design

  • PCBA 100% coating coverage

  • Wide tooth pitch radiator

  • Easy cleaning and replacement fan

  • Provide IP5X options

  • Wide voltage range

  • High adaptability EMC characteristics

  • RFI switch

  • ≥37kW models built-in DC choke

  • Intelligent heating management system

Excellent User Friendliness 
 
  • Easy operation

  • IO board customization

  • Smaller size

  • Multiple installation mode

 

Excellent Control Performance

  
 

 

  
Tech. Specifications
Item  Specification
Power supply Supply voltage

Single/three phase 200~240V -20%~+10%;

  Three phase 380~480V -20%~+10%;

Frequency  48-62Hz;
Max. imbalance   3% ;
Motor output Output voltage   Three phase  0-100% of supply voltage
Output frequency   V/F : 0-400Hz , VVC+: 0-200Hz;

IO

board

control

terminals

 

   
 Input

  6 digital inputs (1 supports pulse input, pulse range: 1Hz~100kHz);

  2 analog input, both can receive voltage or current signals.
 Output

  2 digital output (1 supports pulse output, pulse range: 1Hz~100kHz);

  2 relay output;

  2 analog input (1 can be selected as current output or voltage output via jumper switch).
 Power supply

  1 +10V, max current output 10mA;

  1 24V, max current output 200mA;
 Communication  RS+, RS-, max baud rate 115200bit/s;
 Display   8 segments, 5 numeric displays   Display frequency, warnings, status and so on;
 Indicator  Light FWD, REV, HZ, A, RPM display various status of the drive; 
 Data read-outs   Frequency setting, output frequency, feedback value, output current, DC link voltage, output voltage, output power, input terminals state, output terminals state,  analogue input , analogue output, 1-10 fault records and accumulated working time etc.;
 Environment     Enclosure  IP20;
 Ambient temperature  10℃~50℃, derating use when over 40℃;
 Humidity  5%-85% (95% without condensation);
 Vibration test  ≤75kW: 1.14g;
 ≥90kW: 0.7g;
 Max. altitude above sea level  1000m, derating use when more than 1000 meters;
 Motor cable length  Shield cable: 50 meters; Unshield cable: 100 meters;
Others  DC choke  ≥37kW Built-in
 Braking unit

 ≤22kW Built-in

Product Functions
Main control functions Control mode V/F, VVC+;
Start torque 0.5Hz 150%;
Overload capacity 150% 60s, 200% 1s;
PWM switch frequency 2k~16kHz ;
Speed setting resolution

Digital: 0.001Hz;

Analogy: 0.5‰ of the max. operating frequency ;

Speed open-loop control accuracy

30~4000 rpm: tolerance±8 rpm;
Control command source LCP, digital terminal, local bus;
Frequency setting source LCP, analog, pulse, local bus;
Ramp control Selectable 4-speed steps ramp up and down times 0.05-3600.00s;
Basic Functions Speed Open-loop Control; Process Closed-loop Control; Torque Open-loop Control; AMA Function; Motor Magnetisation; Slip Compensation; Torque compensation; Automatic Voltage Regulation;  V/F Control, DC Brake; AC brake; Speed Limit; Current Limit; Flying Start; Reset Function; Counter; Timer;  
Application Functions Wobble Function;  Jogging;  Multi-speed  Control via Digital input; SLC(including Order Control and Parallel Control); Mechanical Braking; UP/DOWN ; Catch up /Slow down; Relative Scaling Reference etc.

Protection

Functions
Missing Motor Phase Protection; Low-voltage Protection; Over-voltage Protection; Over-current Protection; Output Phase Loss Protection; Output Short Circuit Protection; Output Grounding Fault Protection; Motor Thermal Protection; Live Zero Timeout Function; AMA Fails; CPU Fault; EEPROM Faults; Button freeze; Duplicate Fails; LCP Invalid; LCP Incompatible; Parameter Read-only; Reference Out of Range; Invalid While Running etc.
Particular Specifications
Model   Input voltage

Input current

(A)

Output current

(A)

Rated power

(kW)

Power

Dissipation

 (W)

Air flow rate

(m3/h)

Net weight

(kg)

HLP-A1000D3721 1x200-240V 7.0 2.5 0.37 17.7 51 1.3
HLP-A1000D7521 1x200-240V 13.9 5.0  0.75  33.3 51 1.3
HLP-A10001D521 1x200-240V 20.6   7.5 1.5   53.8 51 1.3 
HLP-A10002D221 1x200-240V 30.4 11 2.2 75.0 51 1.3
HLP-A10003D721 1x200-240V 49.7 17 3.7 115.7 51 2.0
HLP-A10005D521 1x200-240V 62.4 25 5.5 160 124 5.6
HLP-A10007D521 1x200-240V 84 32 7.5 225 230 7.8
HLP-A1000D3723 3x200-240V 4.0 2.5 0.37 16.8 51 1.3
HLP-A1000D7523 3x200-240V  8.0  5.0  0.75 31.5 51 1.3
HLP-A10001D523 3x200-240V 12.0 7.5 1.5 51.0 51 1.3
HLP-A10002D223 3x200-240V 17.7  11.0 2.2 73.7 51 1.3

HLP-A10003D723

3x200-240V 27.2 17 3.7 110.9 51 2.0 
HLP-A10005D523 3x200-240V 35.1   25 5.5  155  124 5.6
HLP-A10007D523 3x200-240V 43.4   32 7.5  210 124  5.6
HLP-A100001123 3x200-240V 61 45 11 323  272  7.8 
HLP-A100001523  3x200-240V  73 61  15  447 300  18.5 
HLP-A1000D7543  3×380-440V  3.7 2.3   0.75   38.5   51   1.3 
3×440-480V  3.2 2.1 
HLP-A10001D543  3×380-440V 6.4  1.5   49.0   51   1.3  
3×440-480V
5.5  3.6 

HLP-A10002D243

3×380-440V  8.9  5.6  2.2   65.2   51   1.3  
3×440-480V
7.7  5.1 

HLP-A10004D043 

3×380-440V  15.8  9.9  4.0   122.9   51   2.0  
3×440-480V
13.6
HLP-A10005D543  3×380-440V   21.3 13.3  5.5   139.4   51   2.0  
3×440-480V
18.4  12.1 
HLP-A10007D543   3×380-440V   28.3  17.7  7.5   211.6   68   2.5  
3×440-480V  24.4  16.1 

HLP-A100001143 

3×380-440V  35.9  25  11  262.4  124  5.8  
3×440-480V 
31.4  22.7

HLP-A100001543 

3×380-440V  43.4  32  15   339.3   170  5.8  
3×440-480V 
38.8  29.1 

HLP-A10018D543 

3×380-440V  51.5  38  18.5   418.0   230   8  
3×440-480V 
46.1  34.5

HLP-A100002243  

3×380-440V   61.0  45  22   468.2   272    8 
3×440-480V   54.5  40.9 

HLP-A100003043  

3×380-440V   73 61  30    676.3   303  19  
3×440-480V  64 52
HLP-A100003743  3×380-440V    72 75  37   795  374   22  
3×440-480V   65 68

HLP-A100004543  

3×380-440V    86  91 45  974.8   408    26 
3×440-480V  80 82

HLP-A100005543  

3×380-440V   110  112 55    1246   476   26 
3×440-480V 108  110

HLP-A100007543

3×380-440V   148  150  75  1635    595   37 
3×440-480V
 135  140
HLP-A100009043   3×380-440V  175 180 90  2204    646  60  
 3×440-480V  154 160
HLP-A100011043  3×380-440V 206  215  110   2600   714   60  
3×440-480V  183 190
 HLP-A100013243  3×380-440V 251 260  132   3178   850   60 
3×440-480V 231 240
HLP-A100016043  3×380-440V 304 315 160  3689  1029   99  
3×440-480V 291 302
HLP-A100018543  3×380-440V  350 365  185  4268   1190   99  
3×440-480V 320 335
HLP-A100020043   3×380-440V 381 395 200  4627   1292   99  
3×440-480V 348 361
HLP-A100022043   3×380-440V 420 435 220  4935   1411   99  
 3×440-480V 383 398 
HLP-A100025043   3×380-440V  472  480  250  5323  1564   250  
3×440-480V  436  443
HLP-A100028043   3×380-440V  525  540  280  6543  1700   250  
3×440-480V  475 490 
HLP-A100031543    3×380-440V   590  605  315  7251  1870  250 
3×440-480V  531 540 
HLP-A100035543  
3×380-440V  647  660  355  7497   2125   250  
3×440-480V   580 590 
HLP-A100041543    3×380-440V   718  745  415  8284   2380  250 
3×440-480V    653  678 
Installation Dimensions

 

CaseVoltage & Power Dimensions(mm)
  1x200-240V 3x200-240V 3x380-480V W H D W1 H1 W2 d
A0  0.37-1.5kW  0.37-1.5kW  0.75-2.2kW 125 210 152 104 194 - 4.5
A1  2.2-3.7kW  2.2-3.7kW  4.0-5.5kW 145 250 167 124 230 - 4.5
A2  -  -  7.5kW 155 263 177 133 243 4.5
A3 5.5kW
5.5-7.5kW  11-15kW 192 365 189 150 340 6.5
A4 7.5kW
11kW  18.5-22kW 216 420 194 150 395 6.5
A5-1 15kW  30-37kW  292 517 229 240 492 9
A5-2 45-55kW 292 562 249 240 537 9
A6 - - 75kW  292 665 277 240 640 9
 A7 - 90-132kW  350  799  375  220  765 280 10.5
 A8 160-220kW  486  900 390 345  863 410 10.5
 A9 - - 250-415kW  600 1568 509 424  304 - 15